#462 monitor should not send SIGINT when interrupted in interactive mode
Closed: Fixed Opened by jhrozek.

Right now, when the daemon is running in interactive mode and Ctrl+C is pressed, a child receives SIGINT first. It should only receive SIGTERM to allow signal handlers (such as krb5_finalize) to be run.


Fields changed

milestone: NEEDS_TRIAGE => SSSD 1.3.0

Fields changed

priority: major => minor

Fields changed

owner: somebody => jhrozek

Fixed in 02a5cdc06cd78e9798b71a5d9ebb6d8bcc43d127

fixedin: => 1.3.0
resolution: => fixed
status: new => closed

Fields changed

rhbz: => 0

Metadata Update from @jhrozek:
- Issue assigned to jhrozek
- Issue set to the milestone: SSSD 1.3.0

SSSD is moving from Pagure to Github. This means that new issues and pull requests
will be accepted only in SSSD's github repository.

This issue has been cloned to Github and is available here:
- https://github.com/SSSD/sssd/issues/1504

If you want to receive further updates on the issue, please navigate to the github issue
and click on subscribe button.

Thank you for understanding. We apologize for all inconvenience.